Single storey dwelling (4 bed 6 person = 99sq.m) Two storey dwelling (4 bed 6 person = 107sq.m) Three storey dwelling (4 bed 6 person = 113sq.m) začať sa učiť
|
|
Standardy Mieszkaniowych standartów
|
|
|
For dwellings designed for more than 6 people, at least 10sq.m. gross internal area should be provided for each additional person. začať sa učiť
|
|
Powierzchnia wewnętrzna brutto
|
|
|
Dwelling plans should demonstrate that dwellings will accommodate the furniture, access and activity space requirements relating to the declared level of occupancy. začať sa učiť
|
|
|
|
|
The minimum width of hallways and other circulation spaces inside the home should be 900mm. This may reduce to 750mm začať sa učiť
|
|
|
|
|
Minimum clear opening width of doorway (mm) = 750 začať sa učiť
|
|
|
|
|
Living / dining / kitchen The following combined floor areas for living / kitchen / dining space should be met: 2 person = 23sq.m. 3 person = 25sq.m. 4 person= 27sq.m. 5 person= 29sq.m. 6 person= 31sq.m. začať sa učiť
|
|
Salon / jadalnia / kuchnia
|
|
|
Designed level of occupancy začať sa učiť
|
|
|
|
|
The minimum width of the main sitting area should be 2.8m in 2-3 person dwellings and 3.2m in dwellings designed for four or more people. začať sa učiť
|
|
|
|
|
Dwellings with three or more bedrooms should have two living spaces, for example a living room and a kitchen-dining room. Both rooms should have external windows. začať sa učiť
|
|
|
|
|
Both rooms should have external windows. If a kitchen is adjacent to the living room, the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement. začať sa učiť
|
|
|
|
|
začať sa učiť
|
|
|
|
|
the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement. začať sa učiť
|
|
|
|
|
There should be space for turning a wheelchair in dining areas and living rooms and basic circulation space for wheelchairs elsewhere začať sa učiť
|
|
|
|
|
A living room, living space or kitchen dining room should be at entrance level začať sa učiť
|
|
|
|
|
The minimum area of a single bedroom should be 8 sq m. The minimum area of a double or twin bedroom should be 12 sq m. začať sa učiť
|
|
|
|
|
The minimum width of double and twin bedrooms should be 2.75m in most of the length of the room. začať sa učiť
|
|
|
|
|
convenient temporary bed space In homes of two or more storeys with no permanent bedroom at entrance level=, there should be space on the entrance level that could be used as a convenient temporary bed space začať sa učiť
|
|
wygodna tymczasowa sypialnia
|
|
|
Structure above a main bedroom and an accessible bathroom should be capable of supporting a ceiling hoist and the design should allow for a reasonable route between this bedroom and bathroom začať sa učiť
|
|
|
|
|
začať sa učiť
|
|
|
|
|
Dwellings designed for an occupancy of five or more people should provide a minimum of one bathroom with WC and one additional WC. začať sa učiť
|
|
|
|
|
Where there is no accessible bathroom at entrance level=, a wheelchair accessible WC with potential for a shower to be installed should be provided at entrance level začať sa učiť
|
|
|
|
|
A minimum of 5 sq m of private outdoor space should be provided for 1-2 person dwellings and an extra 1 sq m should be provided for each additional occupant. začať sa učiť
|
|
Prywatna otwarta przestrzeń
|
|
|
The minimum depth and width of all balconies and other private external spaces is 1500mm. začať sa učiť
|
|
|
|
|
the designer should demonstrate how good levels of ventilation, daylight and privacy will be achieved in each habitable room and the kitchen. začať sa učiť
|
|
|
|
|
The minimum floor to ceiling height in habitable rooms is 2.5m between finished floor level and finished ceiling level. začať sa učiť
|
|
Wysokość od podłogi do sufitu
|
|
|
A minimum floor to ceiling height of 2.6m in habitable rooms is considered desirable začať sa učiť
|
|
|
|
|
encouraged to do something taller ceiling heights are encouraged in ground floor dwellings. začať sa učiť
|
|
zachęca do zrobienia czegoś
|
|
|
Glazing to all habitable rooms should be not less than 20% of the internal floor area of the room. začať sa učiť
|
|
|
|
|
stair providing easy access In the Lifetime Homes Criteria a stair providing easy access is defined as one having maximum risers of 170mm, minimum goings of 250mm and a minimum width of 900mm measured 450mm above the pitch line. začať sa učiť
|
|
schody zapewnia łatwy dostęp
|
|
|
double loaded (they serve dwellings on each side) začať sa učiť
|
|
|
|
|
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified. začať sa učiť
|
|
|
|
|
communal entrance lobbies začať sa učiť
|
|
|
|
|
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified. začať sa učiť
|
|
|
|
|
The approach to all entrances should preferably be level or gently sloping začať sa učiť
|
|
|
|
|
The approach to all entrances should preferably be level or gently sloping začať sa učiť
|
|
|
|
|
All entrances should be illuminated and, have level access over the threshold začať sa učiť
|
|
|
|
|
All entrances should be illuminated and, have level access over the threshold začať sa učiť
|
|
|
|
|
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach. začať sa učiť
|
|
|
|
|
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach začať sa učiť
|
|
|
|
|
Main entrances should have weather protection and a level external landing. začať sa učiť
|
|
|
|
|
začať sa učiť
|
|
|
|
|
Summary of evidence on proposed housing design standards for the Examination in Public of the draft replacement London Plan začať sa učiť
|
|
|
|
|